ویرگول
ورودثبت نام
پنولیک سنتر
پنولیک سنتر
خواندن ۱۰ دقیقه·۱ سال پیش

بوبین پارکر-parker coils

بوبین های پارکر

parker coils

parker
parker



General Description:
Solenoid Enclosure and Coil Information
Coils are electrical devices that produce
magnetic flux when electrical power is
applied to the windings. Surrounding the
coil is the metal solenoid enclosure
and frame. Together with the plunger
and stop, it forms the magnetic circuit
that operates the valve. Without the
enclosure, the magnetic circuit is not
complete. Without a complete
magnetic circuit, the magnetic field
is reduced and valve performance
suffers. Depending on the coil voltage
and power rating, the pressure rating
of the valve can vary.
Solenoid enclosures come in a variety
of constructions offering varying levels
of protection against the elements
and other forces. NEMA identifies the
different enclosures as “Types” and
NEC sets standards for their safety
and performance.
Integrated coils have an epoxy or
thermoplastic "over-molding" creating
a one-piece coil/enclosure for modularity
and protection from the environment.
The National Electrical Manufacturers
Association (NEMA) recommends
suitable materials and components
to meet each enclosure type. The
enclosures listed here will only meet the
applicable NEMA recommendations
when properly installed and operated
to NEMA specifications and in
accordance with the NEC.
Electrical Characteristics:
Standard Voltages:
AC – 24/60
120/60 110/50
240/60 220/50
DC – 12, 24 &120
For other Voltages – Consult Factory

پارکر
پارکر



Coil Classification:
Class F Standard
Class H Available
Agency Approvals:
Standard valves with NEMA Type 4X
or Explosion Proof solenoid enclosures
are UL Listed and CSA Certified.
DIN coils are UL Recognized. For
additional details, consult factory.
Optional coils feature ATEX
and IECEx Approvals.
Ultra Low Power Coils (Coil Chart 12)
are used on valves with a unique
solenoid operator designed to keep
current draw to a minimum, thus
achieving the extremely low power
consumption of 0.6 watts with no
refresh time required for subsequent
energization. These valves are ideally
suited for use in automated control
systems, applications where minimizing
energy consumption is critical or where
heat rise in the coil must be kept to a
minimum. Due to the low power
consumption, an increased number of
solenoid valves can be driven from the
same power source, reducing the
overall installation cost.
Coil Reference
Coil Portfolio and Solenoid Enclosures
(Integrated Modular Coils and Replacement
Coils for Non-integrated)
Coil
Reference

E2
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Charts 1-3
Integrated Coil Offering
Part
Number Type of Termination* Voltage Wattage Class
CHART 1
AF4C01
1/2" NPT Conduit/18" Leads
24/60 6 F
AF4C05 120/60, 110/50 6 F
AF4C15 240/60, 220/50 6 F
AH4C01
1/2" NPT Conduit/18" Leads
24/60 6 H
AH4C05 120/60, 110/50 6 H
AH4C15** 240/60, 220/50 6 H
AFPH01
DIN 43650A/ISO 4400
24/60 6 F
AFPH05 120/60, 110/50 6 F
AFPH15** 240/60, 220/50 6 F
CHART 2
BF4C01
1/2" NPT Conduit/18" Leads
24/60 10.2 F
BF4C05 120/60, 110/50 10.2 F
BF4C15 240/60, 220/50 10.2 F
BH4C01**
1/2" NPT Conduit/18" Leads
24/60 10.2 H
BH4C05 120/60, 110/50 10.2 H
BH4C15** 240/60, 220/50 10.2 H
BFPH01**
DIN 43650A/ISO 4400
24/60 10.2 F
BFPH05 120/60, 110/50 10.2 F
BFPH15 240/60, 220/50 10.2 F
BHPH01**
DIN 43650A/ISO 4400
24/60 10.2 H
BHPH05 120/60, 110/50 10.2 H
BHPH15 240/60, 220/50 10.2 H
CHART 3
1F4C75 1/2" NPT Conduit/18" Leads 12VDC 9.5 F
1F4C80 24VDC 9.5 F
1H4C75** 1/2" NPT Conduit/18" Leads 12VDC 9.5 H
1H4C80** 24VDC 9.5 H
1FPH75 DIN 43650A/ISO 4400 12VDC 9.5 F
1FPH80 24VDC 9.5 F
1HPH75**
DIN 43650A/ISO 4400
12VDC 9.5 H
1HPH80 24VDC 9.5 H
* 1/2" NPT conduit and DIN coils offer NEMA Types 1, 2, 3, 4 and 4X protection with a suitable conduit installation or mating DIN connector and gasket.
** Not in list price book. Minimum order quantities may apply. Consult factory.

E3
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Charts 4-5
Integrated Coil Offering
Part
Number Type of Termination* Voltage Wattage Class
CHART 4
CF4C01
1/2" NPT Conduit/18" Leads
24/60 11 F
CF4C05 120/60, 110/50 11 F
CF4C15 240/60, 220/50 11 F
CH4C01
1/2" NPT Conduit/18" Leads
24/60 11 H
CH4C05 120/60, 110/50 11 H
CH4C15 240/60, 220/50 11 H
CFPH01
DIN 43650A/ISO 4400
24/60 11 F
CFPH05 120/60, 110/50 11 F
CFPH15 240/60, 220/50 11 F
CHPH01
DIN 43650A/ISO 4400
24/60 11 H
CHPH05 120/60, 110/50 11 H
CHPH15 240/60, 220/50 11 H
CHART 5
DF4C01
1/2" NPT Conduit/18" Leads
24/60 16 F
DF4C05 120/60, 110/50 16 F
DF4C15 240/60, 220/50 16 F
DH4C01**
1/2" NPT Conduit/18" Leads
24/60 16 H
DH4C05 120/60, 110/50 16 H
DH4C15** 240/60, 220/50 16 H
DFPH01
DIN 43650A/ISO 4400
24/60 16 F
DFPH05 120/60, 110/50 16 F
DFPH15 240/60, 220/50 16 F
DHPH01**
DIN 43650A/ISO 4400
24/60 16 H
DHPH05 120/60, 110/50 16 H
DHPH15 240/60, 220/50 16 H
* 1/2" NPT conduit and DIN coils offer NEMA Types 1, 2, 3, 4 and 4X protection with a suitable conduit installation or mating DIN connector and gasket.
** Not in list price book. Minimum order quantities may apply. Consult factory.

E4
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Chart 6
Integrated Coil Offering
Part
Number Type of Termination* Voltage Wattage Class
CHART 6
3F4C75 1/2" NPT Conduit / 18" Leads 12VDC 11.5 F
3F4C80 24VDC 11.5 F
3H4C75**
1/2" NPT Conduit / 18" Leads
12VDC 11.5 H
3H4C80 24VDC 11.5 H
3FPH75 DIN 43650A/ISO 4400 12VDC 11.5 F
3FPH80 24VDC 11.5 F
3HPH75**
DIN 43650A/ISO 4400
12VDC 11.5 H
3HPH80 24VDC 11.5 H
* 1/2" NPT conduit and DIN coils offer NEMA Types 1, 2, 3, 4 and 4X protection with a suitable conduit installation or mating DIN connector and gasket.
** Not in list price book. Minimum order quantities may apply. Consult factory.

E5
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Charts 1-6
Additional Coil Options for Charts 1-6 (Below are replacement coils only; no enclosures except as noted)
Part
Number Type of Termination Voltage Wattage Class
AFSB01
NEMA 1 Splice Box w/ 6" Leaded Coil
24/60 6 F
AFSB05 120/60, 110/50 6 F
AFSB15 240/60, 220/50 6 F
BFSB01*
NEMA 1 Splice Box w/ 6" Leaded Coil
24/60 10.2 F
BFSB05* 120/60, 110/50 10.2 F
BFSB15* 240/60, 220/50 10.2 F
CFSB01
NEMA 1 Splice Box w/ 6" Leaded Coil
24/60 11 F
CFSB05 120/60, 110/50 11 F
CFSB15 240/60, 220/50 11 F
DFSB01*
NEMA 1 Splice Box w/ 6" Leaded Coil
24/60 16 F
DFSB05 120/60, 110/50 16 F
DFSB15* 240/60, 220/50 16 F
1FSB75** NEMA 1 Splice Box w/ 6" Leaded Coil 12 VDC 9.5 F
1FSB80 24 VDC 9.5 F
3FSB75 NEMA 1 Splice Box w/ 6" Leaded Coil 12 VDC 11.5 F
3FSB80 24 VDC 11.5 F
AFEC01* 18" Leaded Coil for NEMA 7/9
hazardous location enclosure
24/60 6 F
AFEC05 120/60, 110/50 6 F
AFEC15 240/60, 220/50 6 F
BFEC01
18" Leaded Coil for NEMA 7/9
hazardous location enclosure
24/60 10.2 F
BFEC05 120/60, 110/50 10.2 F
BFEC15 240/60, 220/50 10.2 F
CFEC01*
18" Leaded Coil for NEMA 7/9
hazardous location enclosure
24/60 11 F
CFEC05 120/60, 110/50 11 F
CFEC15 240/60, 220/50 11 F
DFEC01*
18" Leaded Coil for NEMA 7/9
hazardous location enclosure
24/60 16 F
DFEC05 120/60, 110/50 16 F
DFEC15 240/60, 220/50 16 F
1FEC75* 18" Leaded Coil for NEMA 7/9
hazardous location enclosure
12 VDC 9.5 F
1FEC80 24 VDC 9.5 F
3FEC75 18" Leaded Coil for NEMA 7/9
hazardous location enclosure
12 VDC 11.5 F
3FEC80 24 VDC 11.5 F
* Not in list price book. Minimum order quantities may apply. Consult factory.

E6
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Charts 1-6
DIN Electrical Accessories for Charts 1-6
Part
Number Description
ELECD1 Cable Gland DIN Plug
ELECD2 1/2" Conduit DIN Plug
Additional Coil Options for Charts 1-6 Cont. (Below replacement coils only, no enclosures)
Part
Number Type of Termination Voltage Wattage Class
AHEC01*
AHEC05*
AHEC15*
18" Leaded Coil for NEMA 7/9 hazardous location enclosure
24/60
120/60, 110/50
240/60, 220/50
6 H
BHEC01*
BHEC05*
BHEC15*
18" Leaded Coil for NEMA 7/9 hazardous location enclosure
24/60
120/60, 110/50
240/60, 220/50
10.2 H
CHEC01
18" Leaded Coil for NEMA 7/9 hazardous location enclosure
24/60
11 HCHEC05 120/60, 110/50
CHEC15 240/60, 220/50
DHEC01
DHEC05
DHEC15
18" Leaded Coil for NEMA 7/9 hazardous location enclosure
24/60
16 H120/60, 110/50
240/60, 220/50
IHEC75
IHEC80 18" Leaded Coil for NEMA 7/9 hazardous location enclosure
12 VDC
9.5 H
24 VDC
3HEC75
3HEC80 18" Leaded Coil for NEMA 7/9 hazardous location enclosure
12 VDC
11.5 H
24 VDC
* Not in list price book. Minimum order quantities may apply. Consult factory.

E7
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Charts 1-6
1.640
R1.096
1.350
.430
.640
1.330
2.188
Coil Charts 1-6 Integrated Coil Dimensional Values
1.63
1.67
.89
.48
.69
.674
.674
1.35
.189
Ax4Cxx AxPHxx
1.62
1.95
1.53
1.25

.77
1.61
1.10
2.04
.476
.71
.65
.77
1.53
Cx4Cxx CxPHxx

E8
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Charts 1-6
Valves using coil charts 1-6 (Gold Ring TM brand)
Part Numbering Information: Reference ONLY
1 & 2 3 4 5 6 7 8 9 & 10 11
Connection
Size
Connection
Type
Construction Operation Body
Material
Trim Orifice Size Current
Design Series
Designations
02 1/8"
04 1/4"
06 3/8"
08 1/2"
12 3/4"
16 1"
20 1 1/4"
24 1 1/2"
32 2"
48 3"
F Female Pipe
Thread NPT
2 2-way
3 3-way
4 4-way
H Diaphragm,
Hung
5 Diaphragm,
Pivoted
Edge
S Steam
0 Direct Acting
2 Diaphragm
Center pilot
3 Diaphragm
Hung
4 Diaphragm
Offset pilot
5 Diaphragm
Pivoted Edge
6 Piston
8 Piston piloted
C Normally
Closed
O Normally
Open
U Universal
S 4-Way
Single
Solenoid
1 Brass (Bar
Stock)
2 Brass
(Forging)
3 303 Stainless
Steel (Bar)
5 Brass Nickel
Plate
6 316 Stainless
Steel (Cast)
7 Aluminum
(Bar Stock)
8 316 Stainless
Steel (Bar)
9 Bronze
(Cast)
1 NBR
2 FKM
3 EPDM
4 PTFE
5 Urethane
6 CR
8 FDA EPR
9 Kalrez
D Delrin
K KEL F
Valve orifice diameter in
1/64-inch increments.
Example: a 1/2-inch
orifice diameter has an
orifice size designation
of 32.
ALERT: Table is for interpreting product specifications only. Consult Parker Fluid Control Division
for available combinations not shown in catalog.

E9
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Charts 1-6
Valves using coil charts 1-6 (Gold Ring TM brand)
12 13 14 15 16 & 17
Coil Wattage
AC (nominal)
Coil Wattage
DC (normal)
Coil Class Solenoid Enclosure Coil Termination Coil
Voltage AC
Coil
Voltage
DC
A 6 Watts
B 10.2 Watts
C 11 Watts
D 16 Watts
1 9.5 Watts
3 11.5 Watts
F Standard (Class 155)
H High Temperature
(Class 180)
E Explosion-Proof/
Watertight
G Type 1 Gen. Purpose
M 316 SS Explosion-Proof/
Watertight
O Open Frame
P Epoxy Encapsulated
S Type 1 Splice Box
U 316 SS Explosion-Proof/
Watertight
W Submersible Splice Box
Y Explosion-Proof/
Watertight with Ground
Lead
Z Grounded M
4 Type 4, 4X
C 18" Leads
(Standard)
H DIN
K Screw
S Spade
01 24/60
02 24/50
05 110/50
120/60
10 208/60
15 220/50
240/60
20 440/50
480/60
41 24/60
rectified
42 120/60
rectified
44 240/60
rectified
51 120-
240/60
53 240-
480/60
70
75
80
90
95
6
12
24
120
125
ALERT: Table is for interpreting product specifications only. Consult Parker Fluid Control Division
for available combinations not shown in this catalog.

E10
Parker Hannifin Corporation
Fluid Control Division
1 800 825 8305 (1 800 Valve05)
www.parker.com/fcd
Coil Reference
Coil Chart 7
Integrated Coil Offering
Part Number Type of Termination* Voltage Wattage Class
CHART 7
C111B2
1/2" NPT Conduit / 18" Leads
24/60
10 F
C111P3 120/60, 110/50
C111Q3 240/60, 220/50
C111C1 12VDC
C111C2 24VDC
C111C6 120VDC
C222B2
1/2" NPT Conduit / 18" Leads
24/60
10 H
C222P3 120/60, 110/50
C222Q3 240/60, 220/50
C222C1 12VDC
C222C2 24VDC
C222C6 120VDC
D100B2
DIN 43650A/ISO 4400
24/60
10 F
D100P3 120/60, 110/50
D100Q3 240/60, 220/50
D100C1 12VDC
D100C2 24VDC
D100C6** 120VDC
D200B2
DIN 43650A/ISO 4400
24/60
10 H
D200P3 120/60, 110/50
D200Q3 240/60, 220/50
D200C1 12VDC
D200C2 24VDC
D200C6** 120VDC
* 1/2" NPT conduit and DIN coils offer NEMA Types 1, 2, 3, 4 and 4X protection with a suitable conduit installation or mating DIN connector and gasket.
** Not in list price book. Minimum order quantities may apply. Consult factory.

parkerپارکربوبین پارکرparker coilsشیر برقی پارکر
نمایندگی فروش پمپ های دنده ای آرافن نایین در تهران و کرج پمپ های سری PL و پمپ های پیستونی،هیدروموتور اربیتالی،هیدروموتور چهارپیچ،هیدروموتور دوپیچ،سوپاپ هیدرولیک و فولی کنترل،شیر برقی هیدرولیک
شاید از این پست‌ها خوشتان بیاید