What do you need to know about gas fireplaces:

There are different types of gas fireplaces, not every fireplace has all the same parts. First of all to identify which fireplace you have, a good place to look is the rating plate, The rating plate is located at the bottom of the fireplace usually. So if you find that you’ll be able to find the manufacturer’s name, the model of the fireplace, the serial number of the fireplace, and some other information about the gas input of the fireplace. The controller turning the fireplace on and off like switch or receiver and remote control and low voltage thermostats or toggle side switch. There are many different styles, sizes, and designs available in B.C, natural gas or propane. All gas fireplaces needs, regular service, and maintenance once a year and it’s necessary to ensure proper functionality works and safety inspection after service. Few GAS FIREPLACE WARNING SIGNS

  • Discoloration or dirty on glass
  • Ignition problem when the fireplace is on
  • Gas fireplace turns off itself
  • Soot build-up inside your firebox

Gas Fireplace Thermocouple Troubleshooting:

A thermocouple uses the heat from the pilot light to create millivolts to hold open the magnet in a gas valve, Thermocouples come in different shapes and sizes, Not all fireplaces have Thermocouple, some just have the thermopile too, and some just have the thermocouple. Before you test a thermocouple, you want to make sure the pilot is a strong blue flame, and the thermocouple is clean from build-up, if the pilot is weak or the thermocouple has build-up, it can cause low readings. First, locate where the thermocouple is screwed into the gas valve, Then, unscrew the thermocouple from the gas valve, The readings are taken by placing the red probe from the voltmeter and placing it on the very end of the thermocouple. If the thermocouple is reading less than 7mV, you should replace the thermocouple, So, to recap, the readings to look for are 8 to 30mV, and if the readings are less than 7mV, you should replace the thermocouple. ?

Most Common Gas Fireplaces Problems

peoples search online and in Google when they looking for fireplace common problems answers and Troubleshooting we know all questions and answers as a gas fireplace specialist and fireplace Company, here is few Fireplace common problems and our answers:

  • Why does my gas fireplace keep going out?
  • How do I clean the thermocouple on my gas fireplace?
  • Why my gas fireplace wall switches not working?
  • Why my gas fireplace glass get black soot?
  • Why we smell gas when we call for heat or gas leak?

Call Skylimit heating and gas now for all gas fireplace repair and we answer all your questions.

How To light A Gas Fireplace Pilot Flame

  • First, Read your Gas fireplace owner manual.
  • Open your fireplace control panel.
  • Turn the control knob to the off position for at least 2 minutes.
  • Twist the shutoff valve until it is parallel with the gas line.
  • Move the control knob to the pilot position.
  • Press the control knob down and press the ignition switch.
  • Hold the control knob down for at least 30 seconds.
  • Move the control knob to the on position.
  • And the last step you can turn on your fireplace by a wall switch or remote or even thermostat.

Common gas Fireplace Parts Troubleshooting

Fireplace gas valve: The gas valve, which is the heart of the fireplace, the gas comes into the gas valve and the gas goes out to the main burner and the pilot light and all the control is done through the gas valve, there are different brands of gas valve. Pilot flame assembly: The pilot assembly is typically located a little bit hidden behind the logs and it’s the part that has a small flame and your Thermocouple and Thermopile behind the logs. The piezo sparker: Most fireplaces have a sparker, it’s to spark the pilot light when you manually push or when you call for heat it will spark automatically. The on/off switch: Not every fireplace will have an on/off switch, Some fireplaces are operated from alight switch located on the wall, thermostat or remote. The blower speed control: If the fireplace has a fan it most likely will have a blower speed control which controls the speed of the fan or can turn the fan all the way off.

Gas Fireplace Annual Safety Inspection

All gas fireplaces should be cleaned serviced annually once a year as a B.C safety recommendation. Gas fireplaces using natural gas and can be dangerous and also co hazardous, good cleaning always keeps your family and your house safe, call us today for fireplace cleaning. We send our gas technicians to come and service your gas fireplace sales. Carbon monoxide is an odorless, poisonous gas formed by a gas fireplace, so if your gas fireplace not operating properly its starts leaking, before leaking call us for gas fireplace maintenance and cleaning and keep your family safe. Also if your carbon monoxide detector alarm beeping immediately goes outside and call fortis B.C.

Gas Fireplace Parts Troubleshooting:

how to check the On/Off gas fireplace switch circuit in a millivolt fireplace system, First you will need to make sure there are good thermopile readings before you continue. First, make sure the pilot light is turned on, If the fireplace is not turning on by the switch, a common mistake is that the gas valve has been left in the “pilot” position. The gas valve must be in the on position for the main burner to light up, There are different types of switches for millivolt gas fireplaces, a fireplace may have one switch or a combination of switches. Some switches are like a unit switch or toggle switch, a remote control, a wall thermostat, or a wall switch, Keep in mind that the switch circuit will sometimes have other safety switches in the circuit such as a temperature limit switch, or a door switch. A fast way of checking to see if the main burner is not coming on because of the switch circuit is to put a jumper wire on the valve, so This takes the switch circuit out completely. If the fireplace works with a jumper attached but does not when the jumper is removed, it means there is a problem with the switch circuit, Another way to check if the switches are faulty, is to bypass them.

Electronic Ignition Gas Fireplace

If your fireplace has been turned off for some time you need to reacquaint yourself with your gas fireplace, if your gas fireplace electronic ignition system doesn’t light, we show you basic steps. Electronic ignition system will have similar components refer to your owner’s manual for specific information when you first turn on your fireplace initiate call for heat by turning on a wall switch or using your optional remote control and you don’t see a spark at the pilot hood, Then check to see if there is electricity to the fireplace plug in the transformer it may be concealed and try the switch or remote again. if the electrode is sparking to the pilot hood but there is no flame then check if a manual gas shutoff valve is open, the gas valve may be concealed the manual gas the shutoff valve is closed when the handle is perpendicular to the gas line and open when the handle is inline or straight with the piping. If you have verified that there is electricity to the fireplace and all manual shutoff valves to the fireplace is open gas is turned on and the electrode is sparking to the hood and you have a pilot flame but it doesn’t remain on then some light maintenance is required.

Gas Fireplace Repair, Maintenance, and Cleaning Locations:

If your fireplace has been turned off for some time you need to reacquaint yourself with your gas fireplace, if your gas fireplace electronic ignition system doesn’t light, we show you basic steps. Electronic ignition system will have similar components refer to your owner’s manual for specific information when you first turn on your fireplace initiate call for heat by turning on a wall switch or using your optional remote control and you don’t see a spark at the pilot hood, Then check to see if there is electricity to the fireplace plug in the transformer it may be concealed and try the switch or remote again. if the electrode is sparking to the pilot hood but there is no flame then check if a manual gas shutoff valve is open, the gas valve may be concealed the manual gas the shutoff valve is closed when the handle is perpendicular to the gas line and open when the handle is inline or straight with the piping. If you have verified that there is electricity to the fireplace and all manual shutoff valves to the fireplace are open gas is turned on and the electrode is sparking to the hood and you have a pilot flame but it doesn’t remain on then some light maintenance is required.

شاید از این پست‌ها خوشتان بیاید